If any previously unidentified or unknown underground structures including tanks, vaults, sumps, containment structures, separators, or piping that has previously contained or has the potential to contain hazardous materials is encountered during Site grading activities, the ACDEH LOP and CUPA will be notified of reportable findings within 24-hours and consulted on appropriate next steps. USTs may be identified during grading and Site excavation activities by the presence of vent pipes that extend above the ground surface, product distribution piping that leads to the UST, fill pipes, backfill materials, or the underground structure itself. Other buried structures may not have features that extend above ground surface and could be discovered only after contact with construction equipment.

The site redevelopment plan requires that the entire site is to be excavated and vacated for use as the foundation and basement parking area so any item found, soil, structure or otherwise, needs to be removed and removed properly without endangering our crews or the community. Discovered Structures will be assessed as follows:

  • The structure will be inspected to assess whether it contains any indication of chemical residuals or free-phase liquids other than water. This assessment will be conducted by the Environmental Consultant, and will be based on visual evidence and the results of vapor monitoring using a PID. Under no circumstances will any personnel enter an unknown subsurface structure at any time. If chemicals are not indicated within the structure by the above-referenced means and with ACDEH approval the structure by the above-referenced means and with ACDEH approval the structure may be removed or abandoned in place in a safe manner by the contractor.
  • If liquids or solids are present within the structure, measures will be taken to contain the liquids to avoid spills to the subsurface. Samples will be collected and submitted to a California-certified laboratory for analysis. Liquids or solids may be temporarily drummed, or liquids may be collected by vacuum truck, while analysis is pending. based on analytical results, the liquids or solids will be disposed of under the direction of the Environmental Consultant in accordance with all applicable environmental laws and disposal requirements.
  • If contaminated liquid or solids are present in the structure, the structure will be inspected for physical integrity following the removal of the contaminated media. The Environmental Consultant will document the results of this inspection, including an estimation of the volume and former use of the structure.